GIVE FEEDBACK

Thor HLVD DRM95 20AMP Thor Hard Wired DIN Rail Mount

Thor HLVD DRM95 20AMP Thor Hard Wired DIN Rail Mount
  • Overview
  • Features
  • Specifications
  • Reviews
  • Q & A

Generating Print Page

Thor HLVD DRM95 20AMP Thor Hard Wired DIN Rail Mount

Thor HLVD DRM95 20AMP Thor Hard Wired DIN Rail Mount

  • Brand: Thor
  • MPN: HLVD DRM95 20AMP
  • Part #: SURTHR1001
  • UPC:
  • USB Ports:None
  • Cable Length:N/A
  • Number of Outlets:N/A

Features

This has a processor controlling the voltage regulation. If the voltage changes outside of the "safe" window, 190V low or 270V high, then the HLVD shutsdown the power. The internal processor clock then monitors the voltage and when the voltage returns within the "safe" window it waits 3 minutes before re-activating the power automatically. Thus making sure the connected equipment only ever receives safe power. If the voltage travels outside the "safe" window while the timer is on then the timer re-sets.

Note: Factory delay 180 seconds/3minutes can be adjusted donw to a few seconds if shorter delay required.
When power voltage fluctuates electrical equipment suffers. The HLVD is designed to automatically detect a problem then offer shutdown protection until the danger subsides. Once the voltage returns to a safe level then the HLVD automatically re-activtes power to the circuit. The protection is against both high and low voltage incidents.The HLVD has an inbuilt factory delay of 3 minutes this is primarily because it is designed to protect electric motors, refrigeration and air-conditioing compressors from burning out or blowing up. If a compressor is under load and the power is turned on/off quickly this action can cause a compressor irrepairable damage. If an electric motor is supplied low voltage for a period of time this type of supply can cause the motor to burn out.

The HLVD will allow power to pass through as long as the voltage supply is above 190V (low) or below 270V (high). Should the voltage move out of the predefined "safe" window then the HLVD reacts by offering shutdown protection and cutting supply until the voltage supply returns to the "safe" level. If the power moves in and out of the "safe" level then each incident resets the on board clock count down to reactivation, this feature prevents damage occuring when voltage is unstable or erratic.

The delay can be reduced down to seconds or increased if need be. An example of reducing the delay could be applied to applications where equipment is not pressurised or does not require any lenghty delay. An example would be a lighting circuit, in this example the lights may become damaged if there is too much voltage going through and the HLVD would be a great option to protect the circuit. Other applications may be control equipment or PLC's, printing presses, commercial kitchen equipment, office printers, photocopiers, dishwashers, fridges, freezers, dryers etc.


Protects:

- Whole circuit protection
- Air-conditioners
- Motor/pump burn out protection
- Shutdown protection (auto re-start)
- Compressors
- Housing High Temperature impact Polycarbonate Housing Din Rail Mount

Specifications

Product Dimensions:

70mm x 90mm x 60mm

Supply voltage

240/V AC 50Hz

Maximum current rating

20amps/4800 W (VA)

Reaction Speed

800 m/secs

Detection Voltage

190V to 270V

Delay

180 seconds (3 minutes)

LED combination Green

Ok, Orange = Delay mode

LED combination Red (slow flash)

High Voltage detected, RED (fast flash) = Low Voltage detected

Operating Temperature

-10C/+60C

Model No.

HLVD 20A

Manufacturer Part No: HLVD DRM95 20AMP Brand: Thor Product Type: -
UPC - Product Family: - Shipping Weight: 0.1 kg
PB Part No: SURTHR1001 Product Model: -

Warranty: 12 months local warranty *
* Warranty period is as stated above unless the manufacturer has chosen to specify a longer period.
All warranties are return to base unless otherwise specified.

Reviews

There are currently no reviews for this product

Filter Results

Do you own this product?

Write a review and go into the draw to win great prizes each month! Learn more WRITE A REVIEW

Customer Questions & Answers

Want to know something about this product? Ask a question which other users may be able to answer.

Thor HLVD DRM95 20AMP Thor Hard Wired DIN Rail Mount

  • Brand: Thor
  • MPN: HLVD DRM95 20AMP
  • Part #: SURTHR1001
  • UPC:
PB Tech price: $285.22 Excluding GSTPB Tech price:$328.00 Including GST
Date Created: 17:52, 20-01-2021
Product URL: https://www.pbtech.co.nz/product/SURTHR1001/Thor-HLVD-DRM95-20AMP-Thor-Hard-Wired-DIN-Rail-Mou
Branch
New Stock
On Display
Albany
0
Glenfield
0
Queen Street
0
Auckland Uni
0
Penrose
0
Henderson (Express)
0
St Lukes
0
Manukau
0
Hamilton
0
Tauranga
0
New Plymouth
0
Wellington
0
Hornby
0
Head Office (Web)
0
Christchurch Central
0

Features

This has a processor controlling the voltage regulation. If the voltage changes outside of the "safe" window, 190V low or 270V high, then the HLVD shutsdown the power. The internal processor clock then monitors the voltage and when the voltage returns within the "safe" window it waits 3 minutes before re-activating the power automatically. Thus making sure the connected equipment only ever receives safe power. If the voltage travels outside the "safe" window while the timer is on then the timer re-sets.

Note: Factory delay 180 seconds/3minutes can be adjusted donw to a few seconds if shorter delay required.
When power voltage fluctuates electrical equipment suffers. The HLVD is designed to automatically detect a problem then offer shutdown protection until the danger subsides. Once the voltage returns to a safe level then the HLVD automatically re-activtes power to the circuit. The protection is against both high and low voltage incidents.The HLVD has an inbuilt factory delay of 3 minutes this is primarily because it is designed to protect electric motors, refrigeration and air-conditioing compressors from burning out or blowing up. If a compressor is under load and the power is turned on/off quickly this action can cause a compressor irrepairable damage. If an electric motor is supplied low voltage for a period of time this type of supply can cause the motor to burn out.

The HLVD will allow power to pass through as long as the voltage supply is above 190V (low) or below 270V (high). Should the voltage move out of the predefined "safe" window then the HLVD reacts by offering shutdown protection and cutting supply until the voltage supply returns to the "safe" level. If the power moves in and out of the "safe" level then each incident resets the on board clock count down to reactivation, this feature prevents damage occuring when voltage is unstable or erratic.

The delay can be reduced down to seconds or increased if need be. An example of reducing the delay could be applied to applications where equipment is not pressurised or does not require any lenghty delay. An example would be a lighting circuit, in this example the lights may become damaged if there is too much voltage going through and the HLVD would be a great option to protect the circuit. Other applications may be control equipment or PLC's, printing presses, commercial kitchen equipment, office printers, photocopiers, dishwashers, fridges, freezers, dryers etc.


Protects:

- Whole circuit protection
- Air-conditioners
- Motor/pump burn out protection
- Shutdown protection (auto re-start)
- Compressors
- Housing High Temperature impact Polycarbonate Housing Din Rail Mount

Specifications

Product Dimensions:

70mm x 90mm x 60mm

Supply voltage

240/V AC 50Hz

Maximum current rating

20amps/4800 W (VA)

Reaction Speed

800 m/secs

Detection Voltage

190V to 270V

Delay

180 seconds (3 minutes)

LED combination Green

Ok, Orange = Delay mode

LED combination Red (slow flash)

High Voltage detected, RED (fast flash) = Low Voltage detected

Operating Temperature

-10C/+60C

Model No.

HLVD 20A

Date Created: 17:52, 20-01-2021