Advantech ADAM-4019+-F 8Thermocouple Modbus RS-485 Remote I/O
Advantech ADAM-4019+-F 8Thermocouple Modbus RS-485 Remote I/O
- Brand: Advantech
- MPN: ADAM-4019+-F
- Part #: IPCAVH220044
- UPC:
- Brand: Advantech
- MPN: ADAM-4019+-F
- Part #: IPCAVH220044
- UPC:
Features
Specifications
Reviews
Delivery & Pick-up
Returns & Warranty
Related Promotions
Popular Industrial PCs & IoT
Advantech ADAM-4019+-F 8Thermocouple Modbus RS-485 Remote I/O
- Brand: Advantech
- MPN: ADAM-4019+-F
- Part #: IPCAVH220044
Product URL: https://www.pbtech.co.nz/product/IPCAVH220044/api/files/api/files/api/files/image?path=imgad/aib/CommonX_20260112105717.png
| Branch | New Stock | On Display |
|---|---|---|
| Auckland - Albany | - | |
| Auckland - Glenfield | - | |
| Auckland - Queen Street | - | |
| Auckland - Auckland Uni | - | |
| Auckland - Westgate | - | |
| Auckland - Penrose | - | |
| Auckland - Henderson (Express) | - | |
| Auckland - St Lukes | - | |
| Auckland - Manukau | - | |
| Hamilton | - | |
| Tauranga | - | |
| New Plymouth | - | |
| Palmerston North | - | |
| Petone | - | |
| Wellington | - | |
| Auckland - Head Office | - | |
| Auckland - East Tamaki Warehouse | - | |
| Christchurch - Hornby | - | |
| Christchurch - Christchurch Central | - | |
| Dunedin | - |
Features
Advantech ADAM-4019+ 8Thermocouple Modbus RS-485 Remote I/O
- 8ch thermocouple(can be set to voltage or current)
- Protocols:Modbus RTU,ASCII
- Watchdog timer to recover the system
- 3000VDC isolation protection
- Wiring burned-out detection function
Versatile Input Channels
The Advantech ADAM-4019+ is designed with eight flexible input channels, which can each be individually configured for thermocouple, voltage, or current measurements. This adaptability makes it especially suitable for a variety of industrial applications, as it allows integration with a wide range of sensors and devices, providing users with greater versatility in system design and data acquisition.
Reliable Communication Protocols
Equipped with Modbus RTU and ASCII communication protocols, the ADAM-4019+ ensures seamless interoperability with a broad array of industrial automation and control systems. By supporting these widely adopted protocols, the device can be easily integrated into existing SCADA, PLC, or DCS networks, facilitating remote monitoring and control over the RS-485 serial interface.
Robust System Stability Features
A built-in watchdog timer is featured in the ADAM-4019+ to guarantee system reliability. Should the system experience any operational failures or become unresponsive, the watchdog timer will automatically reset the device, thus minimizing downtime and ensuring continuous operation in mission-critical environments.
Enhanced Safety with Isolation Protection
To safeguard both the device and the connected equipment, the ADAM-4019+ offers 3000VDC isolation protection. This high level of electrical isolation helps prevent voltage spikes, ground loops, or external electrical interference from affecting measurements or damaging sensitive electronics, thereby ensuring both accuracy and durability.
Advanced Diagnostic Functions
The module also includes a wiring burned-out detection feature, which automatically monitors the integrity of sensor wiring. If a wiring fault occurs, the system can promptly alert operators, allowing for quick maintenance and reducing the potential for costly downtime or incorrect readings due to faulty connections.
Specifications
Analog Input
Burn-out Detection
Yes
Input Range
±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, 0~20mA, 4 ~ 20 mA, ±20 mA, 0~100 mV, 0~500 mV, 0~1 V, 0~2.5 V, 0~5 V, 0~10 V
Communications
Interface
RS-485
Environment
Isolation Voltage
3,000 VDC
Operating Temperature
-10~70 °C (14~158 °F)
General
Connectors
2 x 10-pin plug-in screw terminal
Protocol
ASCII command, Modbus/RTU
Power Requirements
Input Voltage
10~30 VDC
Thermocouple Input
Channels
8
Input Type
mA, mV, V, T/C: J, K, T, E, R, S, B, N type
Resolution
16-bit
Sample Range
10 S/s (sum)
Temperature Range
Type J (0~760° C)
Type K (0~1370° C)
Type T (-100~400° C)
Type E (0~1000° C)
Type R (500~1750° C)
Type S (500~1750° C)
Type B (500~1800° C)
Type N (-200~1300° C)
Hardware
Certification
CE, FCC