APC - Schneider AP8959 Rack PDU 2G Switched ZeroU 20A 21
Out of stock
APC - Schneider AP8959 Rack PDU 2G Switched ZeroU 20A 21
- Brand: APC
- MPN: AP8959
- Part #: SURAPC1234117
- UPC:
- Brand: APC
- MPN: AP8959
- Part #: SURAPC1234117
- UPC:
Features
Specifications
Reviews
Delivery & Pick-up
Returns & Warranty
Popular PDUs





APC - Schneider AP8959 Rack PDU 2G Switched ZeroU 20A 21
- Brand: APC
- MPN: AP8959
- Part #: SURAPC1234117

Product URL: https://www.pbtech.co.nz/product/SURAPC1234117/APC---Schneider-AP8959-Rack-PDU-2G-Switched-ZeroU
Branch | New Stock | On Display |
---|---|---|
Auckland - Albany | 0 | |
Auckland - Glenfield | 0 | |
Auckland - Queen Street | 0 | |
Auckland - Auckland Uni | 0 | |
Auckland - Newmarket | 0 | |
Auckland - Westgate | 0 | |
Auckland - Penrose | 0 | |
Auckland - Henderson (Express) | 0 | |
Auckland - St Lukes | 0 | |
Auckland - Manukau | 0 | |
Hamilton | 0 | |
Tauranga | 0 | |
New Plymouth | 0 | |
Palmerston North | 0 | |
Petone | 0 | |
Wellington | 0 | |
Auckland - Head Office | 0 | |
Auckland - East Tamaki Warehouse | 0 | |
Christchurch - Hornby | 0 | |
Christchurch - Christchurch Central | 0 | |
Dunedin | 0 |
Features
Description
RACK PDU 2G, SWITCHED, ZEROU 20A/208V, 16A/230V, (21) C13 & (3) C19
Features
- Network management capabilities - Full-featured network management interfaces that provide standards-based management via web, SNMP and telnet, allows users to access, configure and manage rack PDUs from remote locations to save valuable time, associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements
- Remote individual outlet control - Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment)
- Alarm thresholds - Define alarm thresholds in order to avoid overloaded circuits, network and visual alarms inform the user of possible problems
- Local current monitoring display - The aggregate current draw per rack PDU is displayed on the unit via a digital display, the local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip
- Power delays - Allows users to configure the sequence in which power is turned on or off for each outlet, this helps avoid in rushes at start-up, which can cause overloaded circuits and dropped loads; sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly
- Load indicator LED - Indicates overload and warning conditions based on the user-defined alarm thresholds, alerts users of potential overloaded circuits
- Flash upgradeable - Quickly and easily upgrade firmware via network download for future product enhancements, eliminates the need to replace products already installed in the field when new features are released
- Integrates with StruxureWare data center expert - An IT-ready, scalable access monitoring system that collects, organizes and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
- Rack mountable - Includes horizontal, vertical and toolless-mount varieties; puts power where it is needed most in the racks near the equipment
- Single input power source - Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment; saves time and money during installation by using one branch whip and standard connections
- Wide range of input and output connections
Specifications
Number of Outlets
24
Type
RACK MOUNT PDU
Acceptable input voltage
100-240 VAC +6%, -10%
Maximum input current (phase)
16 A UL (derated)
16 A VDE
16 A PSE
Input frequency
50/60 Hz
Input connection
IEC-320-C20
Input power
3.3 kVA UL
3.7 kVA VDE
4.0 kVA PSE
Output voltage
100-240 VAC
Maximum output current (outlet)
IEC-320-C13: 12 A; IEC-320-C19: 16 A UL (derated)
IEC-320-C13: 10 A; IEC-320-C19: 16 A VDE
IEC-320-C13: 15 A; IEC-320-C19: 16 A PSE
Maximum output current (phase)
16 A UL (derated)
16 A VDE
16 A PSE
Output connections
Twenty-one (21) IEC-320-C13; three (3) IEC-320-C19
Dimensions (H x W x D)
(depth does not include toolless pegs) 179.1 x 5.6 x 4.6 cm (70.5 x 2.2 x 1.8 in)
Maximum elevation (above MSL) - Operating/Storage
0-3 000 m (0-10,000 ft) / 0-15 000 m (0-50,000 ft)
Temperature - Operating/Storage
-5 to 45°C (23 to 115°F) / -25 to 65°C (-13 to 149°F)
Humidity - Operating/Storage
5-95% RH, non-condensing