- Computers & Tablets
IBM ServeRAID M5210 SAS/SATA Controller
Clearance price: Clearance price:$140 00 +GST $161 00 inc GST- Overview
- Features
- Specifications
- Q&A
- Reviews
Generating Print PageIBM ServeRAID M5210 SAS/SATA Controller
CLEARANCECLICK IMAGE TO ENLARGEIBM ServeRAID M5210 SAS/SATA Controller
- Brand: IBM
- MPN: 46C9110
- Part #: IDEIBM469110
- UPC:883436446327
$14000$16100+GST inc GSTStore Pickup: Select your store to check availabilityDelivery: Order now and it ships tomorrow
When will I receive it?Popular SATA & SAS Cards
#1StarTech 4 Port PCIe SATA III Controller Card
$118.50 +GST $136.28 inc GST#2StarTech 2 Port SATA 6Gbps PCI Express SATA Controller Card -...
$57.39 +GST $66.00 inc GST#3IBM ServeRAID M5210 SAS/SATA Controller
$140.00 +GST $161.00 inc GST#4Microsemi Adaptec 8405E v2 Entry RAID Controller 4 Port, 12Gbps,...
$369.56 +GST $424.99 inc GST#5View All SATA & SAS CardsSupermicro Add-on Card S3108L-H8iR, PCIe, 8 Port Internal 12Gb/s...
$884.34 +GST $1,016.99 inc GSTFeatures
The ServeRAID M5210 and M5210e SAS/SATA controllers have the following standard features:
Auto-resume on array rebuild or array reconstruction after the loss of system power
Auto-resume uses non-volatile RAM (NVRAM) to save the rebuild progress during a host reboot or power failure to automatically resume from the last checkpoint. Auto-resume ensures that data integrity is maintained throughout the process. The card supports a number of features that can be implemented without rebooting the server. Applications, such as email and web server, benefit from avoiding downtime during the transition.Online Capacity Expansion
Online Capacity Expansion (OCE) allows the capacity of a virtual disk to be expanded by adding new physical disks or making use of unused space on existing disks, without requiring a reboot.Online RAID Level Migration
Online RAID Level Migration, which is also known as logical drive migration, can migrate a virtual disk from any RAID level to any other RAID level without requiring a reboot. System availability and application functionality remain unaffected.Fast initialization for quick array setup
Fast initialization quickly writes zeros to the first and last sectors of the virtual drive. This feature allows you to immediately start writing data to the virtual drive while the initialization is running in the background.Consistency check for background data integrity
Consistency check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. The consistency check mirrors data when an inconsistent stripe is detected for RAID 1 and re-creates the parity from the peer disks for RAID 5 or RAID 6. Consistency checks can be scheduled to take place periodically.Extensive online configuration options and advanced monitoring and event notification
Management tools provide convenience for the configuration of logical volumes and alerting when errors have occurred or are about to occur.Patrol read for media scanning and repairing
Patrol read is a background sentry service that pro-actively discovers and corrects media defects (bad sectors) that arise normally as a disk drive ages. The service issues a series of verify commands, and if a bad block is discovered, the card's firmware uses RAID algorithms to re-create the missing data and remap the sector to a good sector. The task is interruptible based on controller activity and host operations. The firmware also provides an interface where the patrol read task can be initiated, set up for continuous operation, and terminated from a management application. Patrol read can be activated by a manual command or automatically.Global and dedicated hot spare with revertible hot spare support
A hot spare rebuilds data from all virtual disks within the disk group in which it is configured. ServeRAID can define a physical disk as a hot spare to replace a failed drive. Hot spares can be configured as either global or dedicated. A global hot spare allows any physical drive to be designated as a hot spare. A dedicated hot spare allows the user to assign a hot spare drive to a particular array of the same drive type.Drive roaming
Drive roaming occurs when the physical disks are changed to different ports on the same controller. When the drives are placed on different channels, the controller detects the RAID configuration from the configuration data on the drives.Human Interface Infrastructure (HII) configuration utility for pre-boot array configuration and management
HII is a utility that is built into the ServeRAID controller that allows you to configure drive groups and logical drives before installing or booting the operating system.MegaRAID Storage Manager management software
MegaRAID Storage Manager is an easy-to-use advanced RAID management application that is used across the entire family of ServeRAID M controllers. It allows you to configure, monitor, and maintain drive groups, virtual drives, and advanced features with an intuitive GUI, reducing administrative efforts and simplifying troubleshooting.
Note: RAID 10, 50 and 60 drive groups do not support Online Capacity Expansion and Online RAID Level Migration. RAID 0, 1, 5, and 6 drive groups do not support Online Capacity Expansion and Online RAID Level Migration if two or more virtual drives are defined on a single drive group.Specifications
Product Name
Serveraid M5210 SAS/SATA Control IBM System xManufacturer Part Number
46C9110Product Line
ServeRAIDProduct Model
M5210Product Type
SAS ControllerManufacturer Part No: 46C9110 Brand: IBM Product Type: - UPC 883436446327 Product Family: - Shipping Weight: 0.25 kg PB Part No: IDEIBM469110 Product Model: - Warranty: 12 months *
* Warranty period is as stated above unless the manufacturer has chosen to specify a longer period.
All warranties are return to base unless otherwise specified.Customer Questions & Answers
Want to know something about this product? Ask a question which other users may be able to answer.Question:whats the max. drive capacity supported by this card?Asked by: Steve C. on 15 December 2018Reviews
There are currently no reviews for this productFilter Results
Do you own this product?
Write a review and go into the draw to win great prizes each month! Learn more WRITE A REVIEWIBM ServeRAID M5210 SAS/SATA Controller
- Brand: IBM
- MPN: 46C9110
- Part #: IDEIBM469110
- UPC:883436446327
Clearance price: $140.00 Excluding GSTClearance price:$161.00 Including GSTDate Created: 23:51, 17-02-2019
Product URL: https://www.pbtech.co.nz/product/IDEIBM469110/IBM-ServeRAID-M5210-SASSATA-ControllerBranchNew StockOn DisplayPenrose0North Shore0Manukau0Auckland CBD0Auckland Uni0Henderson0Hamilton0Tauranga0New Plymouth0Wellington0Christchurch0Head Office (Web)2Features
The ServeRAID M5210 and M5210e SAS/SATA controllers have the following standard features:
Auto-resume on array rebuild or array reconstruction after the loss of system power
Auto-resume uses non-volatile RAM (NVRAM) to save the rebuild progress during a host reboot or power failure to automatically resume from the last checkpoint. Auto-resume ensures that data integrity is maintained throughout the process. The card supports a number of features that can be implemented without rebooting the server. Applications, such as email and web server, benefit from avoiding downtime during the transition.Online Capacity Expansion
Online Capacity Expansion (OCE) allows the capacity of a virtual disk to be expanded by adding new physical disks or making use of unused space on existing disks, without requiring a reboot.Online RAID Level Migration
Online RAID Level Migration, which is also known as logical drive migration, can migrate a virtual disk from any RAID level to any other RAID level without requiring a reboot. System availability and application functionality remain unaffected.Fast initialization for quick array setup
Fast initialization quickly writes zeros to the first and last sectors of the virtual drive. This feature allows you to immediately start writing data to the virtual drive while the initialization is running in the background.Consistency check for background data integrity
Consistency check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. The consistency check mirrors data when an inconsistent stripe is detected for RAID 1 and re-creates the parity from the peer disks for RAID 5 or RAID 6. Consistency checks can be scheduled to take place periodically.Extensive online configuration options and advanced monitoring and event notification
Management tools provide convenience for the configuration of logical volumes and alerting when errors have occurred or are about to occur.Patrol read for media scanning and repairing
Patrol read is a background sentry service that pro-actively discovers and corrects media defects (bad sectors) that arise normally as a disk drive ages. The service issues a series of verify commands, and if a bad block is discovered, the card's firmware uses RAID algorithms to re-create the missing data and remap the sector to a good sector. The task is interruptible based on controller activity and host operations. The firmware also provides an interface where the patrol read task can be initiated, set up for continuous operation, and terminated from a management application. Patrol read can be activated by a manual command or automatically.Global and dedicated hot spare with revertible hot spare support
A hot spare rebuilds data from all virtual disks within the disk group in which it is configured. ServeRAID can define a physical disk as a hot spare to replace a failed drive. Hot spares can be configured as either global or dedicated. A global hot spare allows any physical drive to be designated as a hot spare. A dedicated hot spare allows the user to assign a hot spare drive to a particular array of the same drive type.Drive roaming
Drive roaming occurs when the physical disks are changed to different ports on the same controller. When the drives are placed on different channels, the controller detects the RAID configuration from the configuration data on the drives.Human Interface Infrastructure (HII) configuration utility for pre-boot array configuration and management
HII is a utility that is built into the ServeRAID controller that allows you to configure drive groups and logical drives before installing or booting the operating system.MegaRAID Storage Manager management software
MegaRAID Storage Manager is an easy-to-use advanced RAID management application that is used across the entire family of ServeRAID M controllers. It allows you to configure, monitor, and maintain drive groups, virtual drives, and advanced features with an intuitive GUI, reducing administrative efforts and simplifying troubleshooting.
Note: RAID 10, 50 and 60 drive groups do not support Online Capacity Expansion and Online RAID Level Migration. RAID 0, 1, 5, and 6 drive groups do not support Online Capacity Expansion and Online RAID Level Migration if two or more virtual drives are defined on a single drive group.Specifications
Product Name
Serveraid M5210 SAS/SATA Control IBM System xManufacturer Part Number
46C9110Product Line
ServeRAIDProduct Model
M5210Product Type
SAS Controller