Features

PTH450: USB sensor with improved precision for temperature, relative humidity, and atmospheric pressure (±0.1°C/±1.5% RH), equipped with a particle filter and an aluminum tip for harsh environments.

The PTH450 allows for the acquisition of temperature, relative humidity, and atmospheric pressure data in a harmonized manner, thanks to its advanced electronics. As a member of the PTH series, it stands out as the most robust, with its anodized aluminum-coated probe capable of withstanding temperatures of up to 125°C. The compact aluminum probe makes it easy to install in confined spaces, and the integrated filtration membrane provides additional protection against dust.

Furthermore, the probe cable is coated with silicone, making it highly resistant to heat, chemicals, UV radiation, and mechanical stress.

Like all Dracal measurement instruments, the PTH450 works with free software tools, making it an integral part of a DAQ (Data Acquisition) solution. For those looking to integrate the PTH450 into their system, command-line tools and VCP (Virtual COM Port) mode are two possible options. For those who prefer a graphical interface, DracalView is highly recommended.

Easy to use in your applications

- Virtual COM option (VCP)
- dracal-usb-get: command-line data integration tool
- dracal-sensgate-get: command-line tool for wireless access to sensors connected to a SensGate
- RVCP: REST API for wireless access to VCP instruments connected to a SensGate

Multiple integration and code examples, including Python, C, C++, Java, Node.js, C#, Grafana and LabVIEW.

Free data monitoring and calibration software

Be instantly operational with DracalView: Dracal's free data visualization, logging and calibration software

- Works under Windows (Win7/8/10/11 64&32-bit), Mac OS X and Linux
- Simultaneous visualization and logging of an unlimited number of sensors
- Automatic synchronization with Dracal's Wi-Fi gateway
- Easy calibration mechanism open to the end-user

Examples of use

- Reference instrument for calibrating other instruments
- Climatic chamber
- Monitoring environmental conditions
  at the CERN
  in telematics
  in laboratory settings (for ISO purposes, in nuclear physics, for audio product development)
  in environmental engineering

Dimensions

 

Warning: This product should not be used in applications where its failure may cause personal injury.

Note: Data may change without notification, and you are strongly advised to obtain copies of the most recently issued datasheet.

Specifications

What is included

One (1) PTH450 measuring instrument
One (1) USB Cable
Quick installation guide
Data acquisition solution for DAQ system

Temperature (probe)

Operating range

-40°C to 125°C

Extended temperature range

-45°C to 130°C

Accuracy (typical)

±0.1°C (20°C to 60°C)
±0.2°C (-40°C to 20°C)
±0.4°C (60°C to 125°C)

Resolution (typical)

0.015°C

Repeatability (typical)

0.06°C

Long-term drift

<0.03°C/year

Relative humidity (probe)

Operating range

0 to 100%RH

Accuracy at 25°C (typical)

±1.5%RH (0 to 80%RH)
±2%RH (80 to 100%RH)

Accuracy at 0 to 80°C (typical)

±2.0% from 0 to 100%RH,

Resolution (typical)

0.01%RH

Long-term drift (-40 to 125°C)

<0.25%RH/year

Atmospheric (barometric) pressure

Operating pressure range

45 to 110 kPa

Accuracy at 25°C

±0.15 kPa

Extended pressure range

1 to 120 kPa

Overpressure

600 kPa

Resolution

0.0065 kPa

Signal Noise filter

1st Order
Internal factory-calibrated coefficients

ADC resolution

24 bits

Altitude resolution

approx. 10 cm

Sensor IC

MS5611

Long-term drift

±0.1 kPa/year

Probe filters

First filter material

Puncture anodized aluminum

Second filter material

PTFE membrane

Efficiency

>99.99% for particles of 200 nm

Miscellaneous

Sensor cable material

Silicone

Sensor housing

Anodized aluminum

USB cable length

1 meter (3 ft.)

Operating temperature range (USB cable interface)

0°C to 70°C

Powered through

USB

Compliance

RoHS3 and CE

Note

This product can operate at 100 %RH but is not waterproof. Protect the sensor and CPU against direct exposure to water or snow. Extra housing may be required depending on the application.
It is recommended that the probe be installed pointing down to reduce the risk of water infiltration or build-up in the probe.

Manufacturer Part No:
USB-PTH450
Brand:
Dracal
Product Type:
-
UPC
-
Product Family:
-
Shipping Weight:
0.01 kg
PB Part No:
IPCDAL20001
Product Model:
USB-PTH450
Warranty: 12 months *
* Warranty period is as stated above unless the manufacturer has chosen to specify a longer period.
All warranties are return to base unless otherwise specified.

Reviews

There are currently no reviews for this product

Do you own this product?

Write a review and go into the monthly draw Win A $100 PB Tech Gift Card!

Delivery & Pick-up

Potential courier delays: Please note that due to the high volumes currently within the NZ courier network there is potential for some deliveries to be delayed.

Delivery Estimates

The estimated time to ship for each product we sell is detailed on the individual product page just underneath the price. From when your items ship, products typically arrive within 1-2 working days for North Island deliveries and 2-3 working days for South Island deliveries. Rural deliveries may take an extra working day. Bulk & hazard deliveries may take an extra 2-4 working days.

Next Day Delivery

Need your order in a hurry? PB Tech offers next day delivery for local Auckland addresses. Simple place your order before 4pm (provided your items are in stock) and select our next day delivery option in the checkout. T&C's apply. Learn more about Next Day Delivery.

Same Day Delivery

Need your order in a hurry? PB Tech offers same day delivery for Auckland, Hamilton, Wellington and Christchurch. Simple place your order before 1pm (provided your items are in stock) and select one of our same day delivery options 'Evening Delivery' or 'Urgent 3-hour Delivery' in the checkout. T&C's apply. Learn more about Same Day Delivery.

Shipping Costs

Shipping costs vary based on your location and the items being shipped and in some cases shipping may even be FREE.

To calculate what the shipping costs will be for your order, add the items you are interested in to your cart, view the Shopping Cart page, and select your 'Delivery Area' to calculate the shipping cost.

Shipping Security & Insurance

All orders shipped by PB Tech are sent via a courier with a signature required for each delivery. In some cases, and only where you have given the courier company permission to leave orders at a designated location, your order may be delivered without requiring a signature. All orders sent by PB Tech are fully insured in the unlikely event that your item(s) are damaged or go missing in transit.

1 Hour Store Pick-up / Click & Collect

You can pick-up your online order from any of our stores nationwide. You can select which store you want to pick up from at the checkout. Provided the store you select has stock and there's no hold-ups with payment we will have your order ready within 1 hour (during normal trading hours for that store) otherwise it may take up to 5 working days to transfer the stock to the store so your order can be fulfilled. Learn more about our Click & Collect process.

Overseas Shipments

PB Tech regularly ships overseas to Australia and beyond. If you are located in Australia, you can order directly from our Australian site www.pbtech.com/au. If you are from another country you can order from www.pbtech.com

Returns & Warranty

7 day right of exchange

If you change your mind after making a purchase, or realise you have ordered the incorrect item, you can enjoy the peace of mind that we offer a 7 day exchange policy.

To exchange a product, goods must be sealed and unopened, with packaging in original condition, accompanied by a valid receipt dated no more than 7 calendar days from when you request an exchange. A 20% restocking fee may be applied where goods are not returned in sealed, original packaging condition.

If there is not a suitable product that can be exchanged for your returned item you will be offered a credit on your account or gift card based on the value paid at the time of purchase. Items purchased on finance cannot be exchanged for a gift card.

 

Hassle free warranty service

If your product develops a fault within the manufacturer warranty period, you can either contact the manufacturer directly (some manufacturers provide a high level of warranty service - including free pickup or in some cases onsite repair), or return to one of our services centres / stores. Where the product has been directly imported by PB Tech, you need to contact us directly or present the product at any one of our service centres / stores together with your proof of purchase.

If your product develops a fault outside of the manufacturer warranty or PB Tech warranty period, we offer a full repair service and are an authorised repair agent for leading brands such as Samsung, HP, Toshiba, Lenovo and more.

 

Returning a product / making a warranty claim

To contact the manufacturer directly to troubleshoot your product or to request a warranty repair, please view the list of manufacturer / brand warranty contacts (for products imported directly by PB Tech please return to us directly by completing our request a return form).

To return a product to PB Tech directly, please complete our request a return form.

Or view our returns policy for more information.

Dracal USB-PTH450 Atmospheric pressure, temperature and relative humidity sensor with improved accuracy and aluminum probe

  • Brand: Dracal
  • MPN: USB-PTH450
  • Part #: IPCDAL20001
PB Tech price $530.93 Excluding GST PB Tech price $610.57 Including GST

Date Created: 12:30, 17-09-2025
Product URL: https://www.pbtech.co.nz/product/IPCDAL20001/Dracal-USB-PTH450-Atmospheric-pressure-temperature
Branch New Stock On Display
Auckland - Albany -
Auckland - Glenfield -
Auckland - Queen Street -
Auckland - Auckland Uni -
Auckland - Newmarket -
Auckland - Westgate -
Auckland - Penrose -
Auckland - Henderson (Express) -
Auckland - St Lukes -
Auckland - Manukau -
Hamilton -
Tauranga -
New Plymouth -
Palmerston North -
Petone -
Wellington -
Auckland - Head Office -
Auckland - East Tamaki Warehouse -
Christchurch - Hornby -
Christchurch - Christchurch Central -
Dunedin -

Features

PTH450: USB sensor with improved precision for temperature, relative humidity, and atmospheric pressure (±0.1°C/±1.5% RH), equipped with a particle filter and an aluminum tip for harsh environments.

The PTH450 allows for the acquisition of temperature, relative humidity, and atmospheric pressure data in a harmonized manner, thanks to its advanced electronics. As a member of the PTH series, it stands out as the most robust, with its anodized aluminum-coated probe capable of withstanding temperatures of up to 125°C. The compact aluminum probe makes it easy to install in confined spaces, and the integrated filtration membrane provides additional protection against dust.

Furthermore, the probe cable is coated with silicone, making it highly resistant to heat, chemicals, UV radiation, and mechanical stress.

Like all Dracal measurement instruments, the PTH450 works with free software tools, making it an integral part of a DAQ (Data Acquisition) solution. For those looking to integrate the PTH450 into their system, command-line tools and VCP (Virtual COM Port) mode are two possible options. For those who prefer a graphical interface, DracalView is highly recommended.

Easy to use in your applications

- Virtual COM option (VCP)
- dracal-usb-get: command-line data integration tool
- dracal-sensgate-get: command-line tool for wireless access to sensors connected to a SensGate
- RVCP: REST API for wireless access to VCP instruments connected to a SensGate

Multiple integration and code examples, including Python, C, C++, Java, Node.js, C#, Grafana and LabVIEW.

Free data monitoring and calibration software

Be instantly operational with DracalView: Dracal's free data visualization, logging and calibration software

- Works under Windows (Win7/8/10/11 64&32-bit), Mac OS X and Linux
- Simultaneous visualization and logging of an unlimited number of sensors
- Automatic synchronization with Dracal's Wi-Fi gateway
- Easy calibration mechanism open to the end-user

Examples of use

- Reference instrument for calibrating other instruments
- Climatic chamber
- Monitoring environmental conditions
  at the CERN
  in telematics
  in laboratory settings (for ISO purposes, in nuclear physics, for audio product development)
  in environmental engineering

Dimensions

 

Warning: This product should not be used in applications where its failure may cause personal injury.

Note: Data may change without notification, and you are strongly advised to obtain copies of the most recently issued datasheet.

Specifications

What is included

One (1) PTH450 measuring instrument
One (1) USB Cable
Quick installation guide
Data acquisition solution for DAQ system

Temperature (probe)

Operating range

-40°C to 125°C

Extended temperature range

-45°C to 130°C

Accuracy (typical)

±0.1°C (20°C to 60°C)
±0.2°C (-40°C to 20°C)
±0.4°C (60°C to 125°C)

Resolution (typical)

0.015°C

Repeatability (typical)

0.06°C

Long-term drift

<0.03°C/year

Relative humidity (probe)

Operating range

0 to 100%RH

Accuracy at 25°C (typical)

±1.5%RH (0 to 80%RH)
±2%RH (80 to 100%RH)

Accuracy at 0 to 80°C (typical)

±2.0% from 0 to 100%RH,

Resolution (typical)

0.01%RH

Long-term drift (-40 to 125°C)

<0.25%RH/year

Atmospheric (barometric) pressure

Operating pressure range

45 to 110 kPa

Accuracy at 25°C

±0.15 kPa

Extended pressure range

1 to 120 kPa

Overpressure

600 kPa

Resolution

0.0065 kPa

Signal Noise filter

1st Order
Internal factory-calibrated coefficients

ADC resolution

24 bits

Altitude resolution

approx. 10 cm

Sensor IC

MS5611

Long-term drift

±0.1 kPa/year

Probe filters

First filter material

Puncture anodized aluminum

Second filter material

PTFE membrane

Efficiency

>99.99% for particles of 200 nm

Miscellaneous

Sensor cable material

Silicone

Sensor housing

Anodized aluminum

USB cable length

1 meter (3 ft.)

Operating temperature range (USB cable interface)

0°C to 70°C

Powered through

USB

Compliance

RoHS3 and CE

Note

This product can operate at 100 %RH but is not waterproof. Protect the sensor and CPU against direct exposure to water or snow. Extra housing may be required depending on the application.
It is recommended that the probe be installed pointing down to reduce the risk of water infiltration or build-up in the probe.